Services
NanoFEA offers specialized getter design, modeling analysis, and prototyping services
Outgassing Analysis
- Identifying primary outgassing sources from packaging materials (polymers, epoxies, PCBs, sealants, and fibers etc.)
- Designing outgas test from package materials to identify the dominate emissions (N2, O2, CO2, H2, H2O, organics…).
- Assessing hermetic vacuum or N2 filled seals in metal enclosures or glass ampules for customer package materials. Subjecting packaging materials to elevated temperatures (≥150°C) for desired bake out periods under vacuum.
- Conducting Residual Gas Analysis (RGA) to analyze RGA data and evaluate package material outgassing severity. Providing safety-factor-based reliability analysis and recommendations for getter selection and installation.
Custom Gettering Material Design and Getter Prototyping
-
Provide specific gettering material design with desirable electric, thermal, mechanical, and dielectric properties.
-
Gas adsorption modeling analysis, for example, adsorption capacity analysis on specific gas and VOC adsorption from -55oC to 200oC, and under different humidity and pressure.
-
Special getter prototype engineering.
-
Getter prototype initial performance evaluation.